Milestone HF X-ray Generators

The Milestone HF (MS HF) generators come standard with an inuitive APR consoles. All of these generators offer single-tube Rad-only operation up to 150 kV and 50kW (depending on model). Options include AEC (max. 3 channels), Bucky interface (max. 2 Buckys), and 16A household power outlet operation.  


Resources: Brochure

Features

  • Microcontroller operation delivers reliability and accurate exposure parameter management
  • Automatic line compensation
  • One-point (kV, w/AEC), two-point (kV, mAs) and three-point control (kV, mA, sec)
  • Automatic Exposure Control (AEC) can support four solid state (or ionization) detectors (single or three-field)
  • APR operating mode with 100 examinations distributed across 10 anatomical regions
  • Simple and user-friendly technique reprogramming procedure for customized APR charts
  • Automatic parameter correction for adult and child patient size, tissue density and film/screen speed
  • Manual override technology permits the operator to modify the recommended kV, mA and time
  • Sophisticated self-diagnostic capability and descriptive error messages allow for fast and well defined initial diagnosis
  • Compact display and console are ideally suited for small control rooms
  • Automatic tube overload protection; selectable 80 % or 100 % maximal load
  • Optional Automatic Brightness Stabilizer (ABS) produces optimal fluoroscopic images
  • Also available with full color flat panel touch screen display (PCX Series)
  • Supports one or two x-ray tubes in either radiographic or R&F modes
Model / Type Description

MS 450 HF LC SE

32kW, 150kV, 630 mAs single-tube rad for 16A single-phase power lines

32kW stored energy radiographic, single-phase, single-tube high frequency generator. Max. output depends on capacitor pack. kV range: 40-150 kVp. 320mA@100kV max. power. 230 V/16 Amp operation.

MS 550 HF LC SE

40kW, 150kV, 630 mAs single-tube rad for 16A single-phase power lines

40kW stored energy radiographic, single-phase, single-tube high frequency generator. Max. output depends on capacitor pack. kV range: 40-150 kVp. 400mA@100kV max. power. 230 V/16 Amp operation.

MS 650 HF LC SE

50kW, 150kV, 630 mA, 630 mAs single-tube rad for 16A single-phase power lines

50kW stored energy radiographic, single-phase, single-tube high frequency generator. Max. output depends on capacitor pack. kV range: 40-150 kVp. 500mA@100kV max. power. 230 V/16 Amp operation.

MS 450 HF LC

32kW, 150kV, 630 mAs single-tube rad for three-phase (optionally single-phase) power lines

The Milestone MS 450 HF LC 100kHz generator is a 32kW microprocessor controlled single tube, three phase (single-phase optionally) high frequency generator. Anatomically programmed with 100 examinations. Rated at 80kV/400mA, 100kV/320mA, 125kV/250mA, 150kV/200mA. Exposure time: 0.001sec-6sec. 0.5-630mA. AEC electronics are optional.

MS 550 HF LC

40kW, 150kV, 630 mAs single-tube for rad three-phase (optionally single-phase) power lines

The Milestone MS 550 HF STR LC 100 kHz generator is a 40kW microprocessor controlled single tube, three phase (single-phase optionally) high frequency generator. Anatomically programmed with 100 examinations. Rated at 80kV/500mA, 100kV/400mA, 125kV/320mA, 150kV/500mA. Exposure time: 0,001sec-6sec. 0.5-250mA. AEC electronics are optional. Bucky option included.

MS 650 HF LC

50kW, 150kV, 630 mAs single-tube for rad three-phase power lines

The Milestone MS 650 HF LC 100kHz generator is a 50kW microprocessor controlled single tube, three phase high frequency generator. Anatomically programmed with 100 examinations. Rated at 80kV/630mA, 100kV/500mA, 125kV/400mA, 150kV/320mA. Exposure time: 0.001sec-6sec. 0.5-630mA. AEC electronics are optional. Power line rating: 3 x 60A, momentary current: 3 x 100A.

MS 850 HF

65kW, 150kV, 600 mAs single or two-tube rad / RF generator for three-phase power lines

65 kW microprocessor controlled three phase, single or two-tube high frequency generator.- Anatomically programmed with 100 examinations. Rated at max. 800 mA, max. 150 kV. High speed sterter included.

MS 1050 HF

80kW, 150kV, 600 mAs single or two-tube rad / RF generator for three-phase power lines

80 kW microprocessor controlled three phase, single or two-tube high frequency generator.- Anatomically programmed with 100 examinations. Rated at max. 800 mA, max. 150 kV. High speed sterter included.

Latest News

2011.03.25

Remote Support Update

To better service our digitial radiography customers, a new version of remote support is available for download..

2011.01.05

New news

2010.02.08

ECR 2010, Vienna, March 5-8.

Control-X Medical will exhibit at the European Congress of Radiology in EXPO C booth C315..

Read all news...

Back to Top Copyright (C) 2011, Control-X Medical, Ltd. All rights reserved. | Terms and Conditions